Part A What is the coefficient of performance of an ideal heat pump that extracts heat from 5.0 °C air outside and deposits heat inside a house at 24°C? Express your answer to two significant figures and include the appropriate units. COP 1 Previous Answers Correct Part B If this heat pump operates on 1300 W of electrical power, what is the maximum heat it can deliver into the house each hour? Express your answer to two significant figures and include the appropriate units 30 10J Submit Previous Answers Request Answer X Incorrect; Try Again; 5 attempts remainingPart